Opcode/Instruction | Op/En | 64-Bit Mode | Compat/Leg Mode | Description |
---|---|---|---|---|
0F C7 /1 m64 CMPXCHG8B m64 |
M | Valid | Valid* | Compare EDX:EAX with m64. If equal, set ZF and load ECX:EBX into m64. Else, clear ZF and load m64 into EDX:EAX. |
REX.W + 0F C7 /1 m128 CMPXCHG16B m128 |
M | Valid | N.E. | Compare RDX:RAX with m128. If equal, set ZF and load RCX:RBX into m128. Else, clear ZF and load m128 into RDX:RAX. |
NOTES: *See IA-32 Architecture Compatibility section below.
Op/En | Operand 1 | Operand 2 | Operand 3 | Operand 4 |
M | ModRM:r/m (r, w) | NA | NA | NA |
Compares the 64-bit value in EDX:EAX (or 128-bit value in RDX:RAX if operand size is 128 bits) with the operand (destination operand). If the values are equal, the 64-bit value in ECX:EBX (or 128-bit value in RCX:RBX) is stored in the destination operand. Otherwise, the value in the destination operand is loaded into EDX:EAX (or RDX:RAX). The destination operand is an 8-byte memory location (or 16-byte memory location if operand size is 128 bits). For the EDX:EAX and ECX:EBX register pairs, EDX and ECX contain the high-order 32 bits and EAX and EBX contain the low-order 32 bits of a 64-bit value. For the RDX:RAX and RCX:RBX register pairs, RDX and RCX contain the high-order 64 bits and RAX and RBX contain the low-order 64bits of a 128-bit value.
This instruction can be used with a LOCK prefix to allow the instruction to be executed atomically. To simplify the interface to the processor’s bus, the destination operand receives a write cycle without regard to the result of the comparison. The destination operand is written back if the comparison fails; otherwise, the source operand is written into the destination. (The processor never produces a locked read without also producing a locked write.)
In 64-bit mode, default operation size is 64 bits. Use of the REX.W prefix promotes operation to 128 bits. Note that CMPXCHG16B requires that the destination (memory) operand be 16-byte aligned. See the summary chart at the beginning of this section for encoding data and limits. For information on the CPUID flag that indicates CMPXCHG16B, see page 3-205.
This instruction encoding is not supported on Intel processors earlier than the Pentium processors.
IF (64-Bit Mode and OperandSize = 64) THEN TEMP128 ← DEST IF (RDX:RAX = TEMP128) THEN ZF ← 1; DEST ← RCX:RBX; ELSE ZF ← 0; RDX:RAX ← TEMP128; DEST ← TEMP128; FI; FI ELSE TEMP64 ← DEST; IF (EDX:EAX = TEMP64) THEN ZF ← 1; DEST ← ECX:EBX; ELSE ZF ← 0; EDX:EAX ← TEMP64; DEST ← TEMP64; FI; FI; FI;
The ZF flag is set if the destination operand and EDX:EAX are equal; otherwise it is cleared. The CF, PF, AF, SF, and OF flags are unaffected.
#UD | If the destination is not a memory operand. |
#GP(0) |
If the destination is located in a non-writable segment. If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit. If the DS, ES, FS, or GS register contains a NULL segment selector. |
#SS(0) | If a memory operand effective address is outside the SS segment limit. |
#PF(fault-code) | If a page fault occurs. |
#AC(0) | If alignment checking is enabled and an unaligned memory reference is made while the current privilege level is 3. |
#UD | If the destination operand is not a memory location. |
#GP | If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit. |
#SS | If a memory operand effective address is outside the SS segment limit. |
#UD | If the destination operand is not a memory location. |
#GP(0) | If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit. |
#SS(0) | If a memory operand effective address is outside the SS segment limit. |
#PF(fault-code) | If a page fault occurs. |
#AC(0) | If alignment checking is enabled and an unaligned memory reference is made. |
Same exceptions as in protected mode.
#SS(0) | If a memory address referencing the SS segment is in a non-canonical form. |
#GP(0) |
If the memory address is in a non-canonical form. If memory operand for CMPXCHG16B is not aligned on a 16-byte boundary. If CPUID.01H:ECX.CMPXCHG16B[bit 13] = 0. |
#UD | If the destination operand is not a memory location. |
#PF(fault-code) | If a page fault occurs. |
#AC(0) | If alignment checking is enabled and an unaligned memory reference is made while the current privilege level is 3. |